PUN-IPAN specifications

Every PUN-IPAN model on one specification table, with a link to the full parameter page for each model.

PUN-IPAN model specifications

Every PUN-IPAN model on one specification table, with a link to the full parameter page for each model.

ModelChamber volumeGas controlDisplay and monitoringULPA filterModel page
A610-I270 LIndicator pump7" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicatorN/AFull parameters
A610-II270 L0.1% precision sensor7" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracyN/AFull parameters
A610-III270 L1 ppm sensor7" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracyN/AFull parameters
A810-I480 LIndicator pump10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicatorOptionalFull parameters
A810-II480 L0.1% precision sensor10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracyOptionalFull parameters
A810-III480 L1 ppm sensor10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracyOptionalFull parameters
A820480 LO₂ + CO₂ (optional)10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% measurement accuracyOptionalFull parameters
A850-I480 LIndicator pump10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicatorOptionalFull parameters
A850-II480 L0.1% precision sensor10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracyOptionalFull parameters
A850-III480 L1 ppm sensor10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracyOptionalFull parameters
A910-I480 LIndicator pump10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicatorStandardFull parameters
A910-II480 L0.1% precision sensor10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracyStandardFull parameters
A910-III480 L1 ppm sensor10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracyStandardFull parameters
A2000-II1000 L0.1% precision sensor10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracyOptionalFull parameters
P620270 LO₂ 0–25% / CO₂ 0–20%7" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracyOptionalFull parameters
P820480 LO₂ 0–25% / CO₂ 0–20%10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracyOptionalFull parameters
P850480 LO₂ 0–25% / CO₂ 0–20%10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracyOptionalFull parameters
P920480 LO₂ 0–25% / CO₂ 0–20%10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracyStandardFull parameters

How to read this table

Each column is a parameter that changes between models. Options such as ULPA filtration or a single-plate transfer lock are quoted per configuration; anything not shown here is listed on the individual model page or released with the technical datasheet.

Not sure which model fits? Describe the plates and throughput you work with and we will confirm the configuration.