IPAN A850-III Anaerobic Workstation (480 L)
A850-III: 480 L working chamber, 1 ppm sensor, with optional ULPA filtration.

Controlled atmosphere. Reproducible culture.
A850-III: 480 L working chamber, 1 ppm sensor, with optional ULPA filtration.
Anaerobic workstation with a 480 L chamber
- 480 L chamber with 10" touchscreen
- O₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy
- Optional ULPA filtration; single-plate transfer lock standard
Key features
- Chamber volume480 L
- Gas controlO₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy
- Display and monitoring10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy
- Transfer airlock27 L
- ULPA filterOptional
- Single-plate transfer lockStandard
Specifications
Published parameters for A850-III. Items not listed here are documented in the technical datasheet.
| Sample and handling | |
|---|---|
| Type | Anaerobic |
| Access ports | Bare-hand direct access; rigid sealing plug with magnetic sleeve cover |
| Chamber and gas control | |
| Chamber volume | 480 L |
| Temperature range | Ambient +4 to 48 °C |
| Gas control | O₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy |
| Gas supply | 1× mixed gas 10% H₂ / 5% CO₂ / 85% N₂ + 1× high-purity N₂ (≥ 99.9%); 40 L standard cylinders |
| Inlet pressure | Inlet pressure ≥ 2.5 bar (regulator on each cylinder) |
| Purge flow | Purge flow 25 L/min |
| Gas connector | 6 mm inlet tubing |
| Disinfection | Full chamber including front panel accepts UV and alcohol disinfection; built-in 254 nm UV lamp and alcohol spray bottle |
| Data and software | |
| Data interface | PC connection for external monitor and software; data export supported |
| Display and monitoring | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy |
| Alarms and safety | Water-level and gas-shortage alarms; leak self-test, live monitoring, automatic pressure relief and gas cut-off on fault |
| Temperature accuracy | ±0.1 °C accuracy; ±0.5 °C uniformity at 25 °C |
| Installation and delivery | |
| Power | 220 V ±10%, 50/60 Hz, 300 W, earthed |
| Installation space | 1500 × 800 × 800 mm bench space; level and stable surface |
| Transfer airlock | 27 L |
| ULPA filter | Optional |
| Removable panels | Side panels removable; front panel removable (optional) |
| Single-plate transfer lock | Standard |
Options and accessories
Options are quoted against the final configuration; availability depends on the model and region.
| ULPA filtration | Optional |
|---|---|
| Single-plate transfer lock | Standard |
| Transfer airlock | 27 L |
| Gas connector | 6 mm inlet tubing |
| Data interface | PC connection for external monitor and software; data export supported |
Downloads and documentation
Frequently asked questions
What working chamber does the A850-III have?
The A850-III has a 480 L working chamber.
What atmosphere can it hold?
O₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy.
How are parameters monitored?
10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy.
All PUN-IPAN models
Every PUN-IPAN configuration on one table, so the model can be chosen by chamber, control level and options rather than by name alone.
| Model | Chamber volume | Gas control | Display and monitoring | ULPA filter | Model page |
|---|---|---|---|---|---|
| A610-I | 270 L | Indicator pump | 7" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator | N/A | Details |
| A610-II | 270 L | 0.1% precision sensor | 7" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy | N/A | Details |
| A610-III | 270 L | 1 ppm sensor | 7" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy | N/A | Details |
| A810-I | 480 L | Indicator pump | 10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator | Optional | Details |
| A810-II | 480 L | 0.1% precision sensor | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy | Optional | Details |
| A810-III | 480 L | 1 ppm sensor | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy | Optional | Details |
| A820 | 480 L | O₂ + CO₂ (optional) | 10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% measurement accuracy | Optional | Details |
| A850-I | 480 L | Indicator pump | 10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator | Optional | Details |
| A850-II | 480 L | 0.1% precision sensor | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy | Optional | Details |
| A850-III (this model) | 480 L | 1 ppm sensor | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy | Optional | You are here |
| A910-I | 480 L | Indicator pump | 10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator | Standard | Details |
| A910-II | 480 L | 0.1% precision sensor | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy | Standard | Details |
| A910-III | 480 L | 1 ppm sensor | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy | Standard | Details |
| A2000-II | 1000 L | 0.1% precision sensor | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy | Optional | Details |
| P620 | 270 L | O₂ 0–25% / CO₂ 0–20% | 7" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracy | Optional | Details |
| P820 | 480 L | O₂ 0–25% / CO₂ 0–20% | 10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracy | Optional | Details |
| P850 | 480 L | O₂ 0–25% / CO₂ 0–20% | 10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracy | Optional | Details |
| P920 | 480 L | O₂ 0–25% / CO₂ 0–20% | 10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% control accuracy | Standard | Details |
Talk to us about your workflow
Tell us what you run today and we will map the configuration that fits.