IPAN Anaerobic and Microaerophilic Workstation

Positive-pressure anaerobic and microaerophilic workstation with forced convection, Super-Pd oxygen removal and full-chamber bio-decontamination.

A controlled anaerobic and microaerophilic environment
OVERVIEW

A controlled anaerobic and microaerophilic environment

The chamber provides an oxygen-free or low-oxygen environment for the inoculation, isolation and cultivation of anaerobic bacteria. Optional UV lamps and high-efficiency ULPA filters greatly reduce the risk of contamination inside the working chamber.

  • Positive-pressure chamber with straight-in, straight-out sample transfer
  • Directional airflow keeps temperature, humidity and gas concentration uniform
  • Chemical oxygen removal — no vacuum pump to maintain or replace

Design features

Positive-pressure design

The chamber runs at positive pressure, so samples and both hands can pass straight in and out without an airlock cycle.

Forced convection circulation

Directional air-duct technology circulates the chamber atmosphere so temperature, humidity and gas concentration stay uniform — and the whole environment recovers quickly after a transfer.

Full-chamber bio-decontamination

Construction uses ageing-resistant organic material tested to National Physical Laboratory standards. The interior is compatible with UV-Light, VHP and Clorox decontamination, and incoming air passes a standard biological sterilisation system.

No airlock pumping

Bare-hand operation is faster and uses less gas. Chemical oxygen removal is prepared in advance, which avoids the maintenance and replacement cost of a vacuum pump.

Explosion-protected design

A built-in splash-proof PUD power socket supports external equipment, with arc-protected circuitry and explosion-proof heaters.

Alarm and indication system

Low-pressure and power-failure alarms, airflow / temperature / anaerobic-level indication, and a leak alarm that actively shuts the inlet valve when a leak is detected.

Super-Pd oxygen-removal catalyst

Eight times the oxygen-removal capacity of standard palladium pellets, over four years of service life, oxygen concentration down to 5 ppm or lower, and no routine drying or reactivation.

Biological detoxifier

Carmolesive detoxifier with more than two years of service life removes growth-inhibiting impurities from the chamber atmosphere.

Applications

Food microbiology testing

Environmental microbiology research

Gut microbiome research

Medical microbiology research

Agricultural microbiology — rhizosphere flora, veterinary probiotics, aquatic pathogens, ecological fertiliser research

Pharmaceutical microbiology testing

Standards referenced by this application set: GB 4789.5-2012, GB 4789.13-2012, GB 4789.34-2012, GB/T 4789.26-2013; Chinese Pharmacopoeia 2020 Volume IV general chapters 1101, 1421, 3301 and 1106.

Low-oxygen applications

Beyond microbiology, the low-oxygen configuration is used for neuron, cardiomyocyte, stem cell and tumour cell research, vaccine development, antibody therapeutics, CAR-T cell therapy, IVF, and microaerophilic bacteria work.

Configuration, chamber volume and fitting options depend on the plates you work with and how many operators need access at once — confirm with us before ordering.