IPAN A910 Anaerobic Workstation with ULPA (480 L)
480 L anaerobic workstation with ULPA filtration as standard and a larger installation envelope, in three oxygen-monitoring tiers.

480 L anaerobic workstation with ULPA as standard
480 L anaerobic workstation with ULPA filtration as standard and a larger installation envelope, in three oxygen-monitoring tiers.
- 480 L chamber with ULPA filtration as standard
- Larger installation envelope: 1500 × 850 × 850 mm
- Three oxygen tiers: indicator, 0.1% precision sensor, 1 ppm sensor
Model range
Every model listed here shares the same platform; the columns shown are the ones that differ between them.
| Model | Gas control | Display and monitoring |
|---|---|---|
| A910-I | O₂ ≤ 5 ppm; anaerobic indicator pump with high-sensitivity indicator | 10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator |
| A910-II | O₂ ≤ 5 ppm; precision oxygen sensor, 0.1% reading accuracy | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy |
| A910-III | O₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy |
What changes between models
ULPA filtration as standard
Unlike the A810/A850 series, A910 ships with a ULPA filter, and the installation envelope grows to 1500 × 850 × 850 mm.
Three oxygen tiers
A910-I uses an indicator pump, A910-II a precision sensor at 0.1%, and A910-III a ppm-level sensor at 1 ppm.
Full specifications — A910-II
Specifications for the A910-II configuration. Other models in this series differ only in the ' 'fields listed under Model range.
| Sample and handling | |
|---|---|
| Type | Anaerobic |
| Access ports | Bare-hand direct access; rigid sealing plug with magnetic sleeve cover |
| Chamber and gas control | |
| Chamber volume | 480 L |
| Temperature range | Ambient +4 to 48 °C |
| Gas control | O₂ ≤ 5 ppm; precision oxygen sensor, 0.1% reading accuracy |
| Gas supply | 1× mixed gas 10% H₂ / 5% CO₂ / 85% N₂ + 1× high-purity N₂ (≥ 99.9%); 40 L standard cylinders |
| Inlet pressure | Inlet pressure ≥ 2.5 bar (regulator on each cylinder) |
| Purge flow | Purge flow 25 L/min |
| Gas connector | 6 mm inlet tubing |
| Disinfection | Full chamber including front panel accepts UV and alcohol disinfection; built-in 254 nm UV lamp and alcohol spray bottle |
| Data and software | |
| Data interface | PC connection for external monitor and software; data export supported |
| Display and monitoring | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy |
| Alarms and safety | Water-level and gas-shortage alarms; leak self-test, live monitoring, automatic pressure relief and gas cut-off on fault |
| Temperature accuracy | ±0.1 °C accuracy; ±0.5 °C uniformity at 25 °C |
| Installation and delivery | |
| Power | 220 V ±10%, 50/60 Hz, 300 W, earthed |
| Installation space | 1500 × 850 × 850 mm bench space; level and stable surface |
| Transfer airlock | 27 L |
| ULPA filter | Standard |
| Removable panels | Side panels removable; front panel removable (optional) |
| Single-plate transfer lock | Standard |
Documentation and validation
Installation drawings, gas-supply requirements and validation records are supplied with each unit. ' 'For a configuration review, send us your plate types and throughput and we will ' 'confirm the model that fits.