IPAN A810 / A850 Anaerobic Workstation (480 L)
480 L anaerobic workstation in seven configurations: A810-I/II/III, A850-I/II/III (same specification, alternative model code) and the A820 variant with O₂ and CO₂ control.

480 L anaerobic workstation in seven configurations
480 L anaerobic workstation in seven configurations: A810-I/II/III, A850-I/II/III (same specification, alternative model code) and the A820 variant with O₂ and CO₂ control.
- 480 L chamber with a 10-inch touchscreen and 27 L transfer airlock
- A810 and A850 are identical machines under two model codes
- A820 variant adds CO₂ measurement and optional CO₂ control
Model range
Every model listed here shares the same platform; the columns shown are the ones that differ between them.
| Model | Gas control | Display and monitoring |
|---|---|---|
| A810-I | O₂ ≤ 5 ppm; anaerobic indicator pump with high-sensitivity indicator | 10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator |
| A810-II | O₂ ≤ 5 ppm; precision oxygen sensor, 0.1% reading accuracy | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy |
| A810-III | O₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy |
| A850-I | O₂ ≤ 5 ppm; anaerobic indicator pump with high-sensitivity indicator | 10" touchscreen; live temperature, humidity and O₂; plus anaerobic indicator pump and indicator |
| A850-II | O₂ ≤ 5 ppm; precision oxygen sensor, 0.1% reading accuracy | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy |
| A850-III | O₂ ≤ 5 ppm; ppm-level oxygen sensor, 1 ppm accuracy | 10" touchscreen; live temperature, humidity and O₂; ppm-level sensor at 1 ppm accuracy |
| A820 | O₂ ≤ 5 ppm; O₂ measurement 0–20% at 0.1%, CO₂ measurement 0–20% at 0.1%; optional CO₂ control | 10" touchscreen; live temperature, humidity, O₂ and CO₂; 0.1% measurement accuracy |
What changes between models
A810 and A850 are the same machine
A810-I/II/III and A850-I/II/III carry identical specifications — the two codes are alternative sales designations, and either can be quoted.
A820 adds CO₂
The A820 variant keeps the 480 L chamber and 10-inch touchscreen but adds CO₂ measurement (0–20% at 0.1%) plus optional CO₂ control alongside anaerobic oxygen levels.
Three oxygen tiers
Within A810/A850 the -I version uses an indicator pump, -II a 0.1% precision sensor, and -III a 1 ppm sensor.
Full specifications — A810-II
Specifications for the A810-II configuration. Other models in this series differ only in the ' 'fields listed under Model range.
| Sample and handling | |
|---|---|
| Type | Anaerobic |
| Access ports | Bare-hand direct access; rigid sealing plug with magnetic sleeve cover |
| Chamber and gas control | |
| Chamber volume | 480 L |
| Temperature range | Ambient +4 to 48 °C |
| Gas control | O₂ ≤ 5 ppm; precision oxygen sensor, 0.1% reading accuracy |
| Gas supply | 1× mixed gas 10% H₂ / 5% CO₂ / 85% N₂ + 1× high-purity N₂ (≥ 99.9%); 40 L standard cylinders |
| Inlet pressure | Inlet pressure ≥ 2.5 bar (regulator on each cylinder) |
| Purge flow | Purge flow 25 L/min |
| Gas connector | 6 mm inlet tubing |
| Disinfection | Full chamber including front panel accepts UV and alcohol disinfection; built-in 254 nm UV lamp and alcohol spray bottle |
| Data and software | |
| Data interface | PC connection for external monitor and software; data export supported |
| Display and monitoring | 10" touchscreen; live temperature, humidity and O₂; precision sensor at 0.1% accuracy |
| Alarms and safety | Water-level and gas-shortage alarms; leak self-test, live monitoring, automatic pressure relief and gas cut-off on fault |
| Temperature accuracy | ±0.1 °C accuracy; ±0.5 °C uniformity at 25 °C |
| Installation and delivery | |
| Power | 220 V ±10%, 50/60 Hz, 300 W, earthed |
| Installation space | 1500 × 800 × 800 mm bench space; level and stable surface |
| Transfer airlock | 27 L |
| ULPA filter | Optional |
| Removable panels | Side panels removable; front panel removable (optional) |
| Single-plate transfer lock | Standard |
Documentation and validation
Installation drawings, gas-supply requirements and validation records are supplied with each unit. ' 'For a configuration review, send us your plate types and throughput and we will ' 'confirm the model that fits.